Release evidence
Measured, not asserted
How we build and test Ozari, what the tests found, and the scope we state openly.
0
Crashes when every field-protocol parser is fuzzed with malformed and hostile traffic, on every build. Hardened by design.
1
Server in control at any moment. The hot standby takes over automatically, in seconds, once it holds the control lease.
SBOM
From day one. Every release is signed, scanned and fully listed.
100%
Of logins, commands and approvals written to the tamper-evident security trail.
From the Ozari release test suite. Ask for the evidence pack to see the reports.
Evidence log
Break it on purpose, before the field does
Our tests assume the network, the devices and the operators will all do something unexpected. Each record says what we tested, how, and where the result is written down.
EV-01 · Quality
41/0
Test packages passing and failing
Unit and integration tests run on every package in every build of Ozari Grid.
Release test suite
EV-02 · Quality
0
Data races
The race detector runs across the whole code base on every build.
Release test suite
EV-03 · Protocols
0
Crashes under fuzzing
Coverage-guided fuzzing of the IEC 104, DNP3, Modbus and gateway parsers on every build, with a corpus replay for regressions. The parsers are hardened against malformed and hostile traffic.
Release test suite
EV-04 · Resilience
40
Hostile connections at once
Malformed, oversized and truncated frames, then a 40-connection flood against a live gateway. No panic and no leaked connections.
Release test suite
EV-05 · Resilience
1
Server in control at a time
We crash the primary server and watch the hot standby take over. It never operates until it holds the control lease, so control never splits between two servers.
Release test suite
EV-06 · Quality
59/59
Deployment validation checks
The deployment validation suite. All 59 checks pass and none fail.
Release test suite
EV-07 · Protocols
18/18
IEC 60870-5-104 conformance tests
The conformance suite, run against the native IEC 104 driver.
Conformance report
EV-08 · Security
100%
On the security trail
Every login, command, approval and change is written to a hash-chained, write-once trail, and every read needs a signed-in session. Your auditor can verify the trail offline.
Release test suite
EV-09 · Security
0
Open security review findings
A pre-release security review. Every finding is fixed and covered by a regression test.
Security review
EV-10 · Protocols
3
Protocols tested with vendor reference servers
IEC 104, IEC 61850 and DNP3 exchanged data and controls with vendor reference servers, and an approved command operated a reference IED.
Interoperability records
EV-11 · Protocols
50/50
Field input and output operations
The Ozari Base regression suite over IEC 104 and IEC 61850, against simulated devices.
Regression report
EV-12 · Security
SBOM
From day one, for every release
Every release ships with a software bill of materials, a vulnerability scan and a signature you can verify. The control plane never speaks raw field protocols; those stay behind the fault-isolated gateway.
Release test suite
Ask for the evidence pack to see the reports behind each record.
Standards
Security standards and best practice
Ozari conforms to the requirements of ISA/IEC 62443 and follows recognised practice for securing operational technology. Each line says how.
| Standard | Status | Why it matters |
|---|---|---|
| ISA/IEC 62443 | Conforms Conforms to the requirements of the ISA/IEC 62443 series, with zones, conduits and an evidence map for each requirement. Target security level SL 2, with support for higher-level controls: dual approval (IEC 62443-3-3 SR 2.1 RE 4, SL 4), supervisor override (SR 2.1 RE 3, SL 3), multi-factor authentication on all networks (SR 1.1 RE 3, SL 4) and audit records on write-once storage (SR 3.9 RE 1, SL 4). | The main security standard for industrial automation and control systems. The evidence map saves your assessor time. |
| IEC 62351-3 and -4 | Built in Mutual TLS in the Ozari Base protocol drivers, following IEC 62351. | Security for power-system protocols: encrypted, authenticated links to the field. |
| IEC 61850-7-2 control model | Supports Every control model, including select-before-operate with enhanced security. The device declares its model and Ozari follows it. | How substation devices take commands safely: reserve the device, operate, then confirm the result. |
| IEC 60870-5-104 and DNP3 (IEEE 1815-2012) | Supports Select-before-operate on both: the select/execute qualifier of IEC 60870-5-101 subclause 7.2.6.26, and DNP3 SELECT and OPERATE. DNP3 Secure Authentication (IEEE 1815-2012 clause 7). | Telecontrol commands that are armed first and then executed, with authenticated control messages on DNP3. |
| NIST SP 800-53 AC-3(2) | Supports Dual authorisation for the actions you define. Automation armed in advance keeps immediate safety responses possible, as the control guidance allows. | The US federal control for dual authorisation of critical actions. |
| NIST SP 800-82 Rev. 3 | Followed Segmented zones, an OT DMZ, one-way data to the enterprise and fail-safe behaviour follow its guidance. | The US guide to securing operational technology, used by utilities around the world. |
| Secure by design | Built in Memory-safe Go, multi-factor authentication, role-based access, a tamper-evident security trail and fail-safe behaviour are part of the product. | Joint guidance from the Australian Cyber Security Centre, CISA and partner agencies: security is the vendor’s job, not an add-on. |
| Software supply chain | Practised An SBOM from day one, plus a vulnerability scan and a signature on every release, recorded in a transparency log. A lean, fully listed set of dependencies, with fuzzing and race testing on every build. SLSA level 1 to 2 practices. | Integrity of the software, from source code to the binary you run. |
| NIST Cybersecurity Framework 2.0 | Supports Ozari controls support its protect, detect, respond and recover functions. | A common language for cyber risk across IT and OT. |
| AESCSF | Supports Controls and evidence help energy operators reach their target maturity. | The Australian Energy Sector Cyber Security Framework, used to assess and improve cyber maturity across the energy sector. |
| NERC CIP | Aligned to intent Aligned to the control intent. Whether it applies is the utility’s decision. | North American security rules for the bulk power system. Most distribution networks are outside their scope. |
| ISA-18.2 | Built in Alarm performance metrics are built in. Alarm rationalisation remains the operator’s task. | The alarm management standard. It helps keep alarm floods and standing alarms under control. |
| IEC 61970 / 61968 (CIM, CGMES) | Tested Core-class import and export, round-trip tested. | The common model for network data, so models move between tools without being typed in again. |
| OCSF and MITRE ATT&CK for ICS | Mapped Findings emitted in OCSF. Detections mapped to ATT&CK for ICS techniques. Mappings, not guarantees. | Shared formats and terms, so your security team can use the findings in its own tools. |
| Field protocols | Varies See the protocol status table. | Each protocol is labelled by how far it has been proven. |
Scope and assumptions
What we want you to know up front
- The security trail is anchored to external write-once storage at go-live.
- Automation that an administrator arms, such as self-healing, acts without a per-action approval. It never skips crew tags, the control lease or the audit.
- Screens on this site show simulated data from the Ozari demonstration network.
Security disclosure
Found a vulnerability? Tell us privately
Please report it through our contact form and choose “Something else”. Include enough detail for us to reproduce it. We will acknowledge your report and work with you on a fix and on disclosure.
Responsible AI
ozari+ advises and never operates, and it can never approve its own improvements. Read how it is designed around the December 2025 AI-in-OT principles, or get our free buyer’s checklist.
Start safely
Begin with a read-only trial